Roll Radiant - For Underfloor Heating Systems

Impact Sound Insulation Roll Radiant
Impact Sound Insulation Underfloor Heating Roll Radiant

Roll Radiant is an exciting new all in one acoustic, thermal and moisture barrier mat designed for use with underfloor heating systems. Based on the original Roll impact sound insulation mat - Roll Radiant has a thermal reflective backing which also acts as a moisture barrier.

This reflecting layer ensures that heat from the underfloor heating pipes radiate back into the room instead of being lost in the substructure beneath.

Roll Radiant can be used with both anhydrite and cement based screeds at thicknesses as low as 50mm. upwards.

Roll is available in 5mm, 7mm and 10mm versions.

Features

  • High acoustic insulation
  • Thermally reflective backing
  • Moisture barrier
  • Impact sound reduction improvement (ΔLw) of up 27dB
  • Made from over 92% recylced materials
  • Can contribute towards LEED accreditation
  • Durable and robust material
  • Quick and easy installation
  • Economical

Roll is perfect for insulation in the following applications:

  • Underfloor heating systems
  • Floors with floating screeds
  • High thickness screeds

Roll Radiant Installation

Description Unit 5mm 7mm 10mm
Density (without anti-stretch backing) kg/m³ 400 335 295
Overall Superficial mass kg/m² 1.8 2.4 2.8
Dynamic Stiffness mn/m³ 29 20 18
Impact Sound Reduction - ΔLw dB 24 26 27
Thermal conductivity coefficient (λ) W/mK 0.099
Resistance factor to water vapour (µ)   125000

Acoustic Performance calculated according to EN 12354